LM PCI optimization: The Pearls from NOBLE, EXCEL, IDEAL-LM & EBC MAIN
A LM PCI from the screened population in NOBLE
Author: Evald H Christiansen, Department of Cardiology, Aarhus University Hospital
CONCLUSION
- LM culotte bifurcation treatment with ORSIRO (3.0 mm and 3.5 mm) is feasible
- Accidental abluminal rewiring is a risk despite POT
- OFDI can be used for evaluating wire positions
- Don’t let the first stent cover the ostium when performing culotte in the LM!