Author: Masahiro Yamawaki, M.D, Ph.D

 

HYPOTHESIS

We hypothesized that the design of the 2-link BES (Nobori) platform, because of its higher possibility of dilating and device access in the SB than that of the 3-link EES(Xience), could improve the angiographic results at the SB orifice.

CONCLUSION

  • 2-link BES did not appear superior to 3-link EES with respect to mid-term maintenance of SB ostial enlargement despite aggressive treatment for SB.
  • Factors other than stent platform design (pre- procedure plaque distribution, location of link on the carina before kissing, bifurcation angle, and strut thickness) might affect ostial SB angiographic and clinical outcome.

 