EBC - ON DEMAND
European Bifurcation Club 2018 – EBC 2018 – Brussels, Belgium
LIMIT THE NUMBER AND LENGTH OF STENTS
How IVUS imaging can reduce the number and length of stent?
Author: Akiko Maehara Columbia University, Cardiovascular Research Foundation, New York
TAKE HOME MESSAGES
- IVUS can inform you appropriate landing zone of stent. ≈50% of plaque burden is recommended.
- The presence of calcified lesion, attenuated plaque (lipidic plaque), and overstretch at landing zone predict stent edge dissection.
- When dissection occur, long (>3mm), large (>60°), deep (>=media), and small lumen (<5mm2) cause edge restenosis.
- IVUS guidance did not decrease the actual stent length compared to PCI without IVUS by appropriate coverage, and reduced future events.
- Side branch of bifurcation lesions are usually negative remodeling (~70- 80%) and cause carina shift after cross-over stenting.