Optimal Provisional Coronary Bifurcation Stenting

European Bifurcation Club 2014, EBC 2014 - Bordeaux, France ADVANCEMENTS IN BENCH TESTING AND COMPUTER MODELING Optimal provisional coronary bifurcation stenting: Final kissing balloon dilatation or not ? Author: Gerard Finet, MD, PhD, Hospices Civils de Lyon, France OBJECTIVES Quantify the mechanical effects of the POT Quantify the differences between: FKB approach (with its modified protocols) after POT approach with no FKB but consecutive POT with SB balloon inflation (re-POT) CONCLUSION Our preliminary results with 25 fractal bifurcation models with Promus Premier® (Boston) : quantitatively validated the mechanical effects of POT showed by comparison with : FKB alone and POT + FKB with symmetric or asymmetric balloon inflaOon pressure thatwithre-POT with SB dilation provides the best mechanical results and is the simplest technique in 1-stent bifurcation strategy. SBO almost free of strut (4.9%) a very low rate of global strut malapposition (2.6%) an almost perfect morphology of the carena and the wall facing the SB ostium a maintained circular cross-sectional area of the MoV (relative elliptic ratio : 1.0) the almost perfect respect of the linear law of coronary artery bifurcation geometry (0.66) We are completing these preliminary results with 25 other fractal bifurcation bench models with Ul#master® stent (Terumo) A total of 50 experimentations in fractal bifurcation bench models.

Lessons from IVUS in bifurcation lesions

European Bifurcation Club 2005, EBC 2005 - Bordeaux, France Lessons from IVUS in bifurcation lesions Author: Gerard Finet, MD, PhD, Claude Bernard University, Lyon, France

Flow dynamics and rheology of bifurcation lesions

European Bifurcation Club 2007, EBC 2007 - Valencia, Spain PARALLEL WORKSHOP DEBRIEFING Flow dynamics and rheology of bifurcation lesions Author: Gerard Finet, MD, Hôpital Cardiologique et Pneumologique L. Pradel, Lyon, France

(re)-Proximal Opimizing Technique in coronary bifurcation stenting with everolimus-Eluting Bioresorbable Vascular Scaffold Fractal Coronary Bifurcation Bench for comparative test between ABSORBTM and XIENCE XpeditionTM

European Bifurcation Club 2015 - EBC 2015 - Athens, Greece BRS in bifurcations (1) (re)-Proximal Opimizing Technique in coronary bifurcation stenting with everolimus-Eluting Bioresorbable Vascular Scaffold Fractal Coronary Bifurcation Bench for comparative test between ABSORBTM and XIENCE XpeditionTM Author: Gérard Finet MD PhD, Hospices Civils de Lyon, France